The physical connection

When working with RS232 it is important to have a good understanding of the general principles of the commnuication standard, so if you are new to the field we recommend you to read this section regarding the RS232 topic.

When trying to find the problems in a serial signal like RS232, a common thing we see is that the wires have been crossed (or let's say, not crossed), because the receiving end of the cable needs to be connected to the transmitting part from the other end. It's like ear and mouth needs to be connected and when it's the other way round it ear on ear or mouth on mouth!

There are small gadgets like the DB9 signal testers you can put in between to test the connectivity, as seen in this article.

Also some of the easy things to check, besides swapping Rx and Tx, is to see if the buad rate (transmission speed) is set correct. On some devices you can choose between different speeds and on others, it's fixed.

In Project Designer it is easy to change the speed, just remember to re-upload to the controller for the changes to take effect.

mceclip1.png

Another external mistake we often see, is that when connecting to projectors and TV's, the manufacturers hunt for the green leaf sticker on the side of their products, often makes it necessary for them to turn off network and RS232 communication, out of the box. It is often called ECO mode or similar, so turn that mode off to make the communication start. An easy way to detect if this should be the case, is that you can control the device, when it is ON, but it is not possible to turn the device ON after you have turned it OFF.

These settings can sometimes be hidden in a service menu, so it can be necessary to contact the support for the given device in order to get the way into this menu.

Device driver:

In Project Designer you will find devices that are "Neets approved" and some that are not, the ones that are, means that we have had the device on the test bench and verified that the timings and commands funciton correct. However on the devices we have launch as "not approved", are just made from the PDF the manufaturer has released and hence there can be errors in the commands, timings and settings for the driver. Therefore check and verify the commands, if you have a command that is not working as intended. If you find an error in one of our released drivers, please let us know, so that we can update it. just contact support@neets.dk and we will correct it.

In the example below there are different ways of writing the same command, but small tweaks is essential for making it work, e.g case sensitivity, CR (Carriage Return) and so on. mceclip5.png

mceclip3.png

mceclip4.png

In the last example you can see that CR is in two bytes (boxes,) meaning that it is two seperate characters. and in HEX format C R is 43h 52h and a CR is 0Dh, so only 1 byte. making a big difference for the RS232 decoder in the device you wish to control.

Same goes for lower and upper case letters, e.g. a lower case "a" is 61h and an upper case "A" is 41h.

Timing

In the timing sections of the device, it is important to keep in mind the importancy of having adjusted the timing correct. Let me give you an example: 

When turning on a TV, the first thing that happens from the controller is that the ON command is sent, then a timer starts and when it runs out, the SOURCE command is sent (this is called the warm-up time). But if the waiting period between the ON command and the SOURCE command is too short, then the TV will not be ready for the SOURCE command, and the command will be missed by the TV. Resulting in the TV might not be on the right SOURCE.

This is all set in the device driver initially, but can be altered from Project Designer after you have added the driver.

In Device Editor you can see the example of the warm up time below:

mceclip6.png

Here in Project Designer you can see the same timer and you can change it here as well, just double tap the numeric value and enter the new value. 

mceclip7.png

Checksum

The transmitted signal is sometimes attached with a checksum calculation, where the sum of all bytes are added to provide a check for the sent message. This to show the receiving end that the command is valid. If the calculation is done wrong, the receiver will simply discard the message!

This is especially important on levels, where the values changes as soon as the user turns the volume up or down. Therefore the checksum will also change and needs to be recalculated by the controller.

There is a complete article on this topic right here.

Extending the signal range

You can use different devices to extend the somewhat limited range of RS232, this can be done with cat-extenders or maybe HDBaseT extenders. Problem is that it has been seen, that these devices adds or subtracts from the command strings sent by the Neets controller.

In these cases it is necessary to investigate the strings sent more thoroughly, more on that in this article.

Terminal software

To see exactly what is transmitted from one end to the other, it is necessary to monitor the signal with a piece of software. Many use an app called Hercules, here at Neets we prefer the product called Docklight.

Read this article on how to use it!